- SKU: FTXM71A + RXM71A
SB.FTXM71A/RXM-A/1 - Standard Inverter - 7.1kW - 1ph - Max. 30m + RXM71A - SPLIT<COMP<H/P
Shipping calculated at checkout.
Price excludes VAT. VAT will be added at checkout.
Free Shipping on Orders Over £500
Easy 30-day Returns
Manufacturer’s Warranty
Couldn't load pickup availability
Product Code: FTXM71A + RXM71A
Searched Code: FTXM71A
Product Details
Wall mounted unit
Attractive, wall mounted design with perfect indoor air quality
Energy Labels
Technical Specifications
| Category | Sub Category | Parameter | Condition | Value | Unit |
|---|---|---|---|---|---|
| Casing | Colour | White | |||
| Control systems | Infrared remote control | ARC466A86 | |||
| Wired remote control | BRC073A1 | ||||
| Dimensions | Unit | Depth | 292 | mm | |
| Height | 298 | mm | |||
| Width | 997 | mm | |||
| Fan | Air flow rate | Cooling | High | 15.8 | m³/min |
| Medium | 13.6 | m³/min | |||
| Low | 11.4 | m³/min | |||
| Silent operation | 9.3 | m³/min | |||
| Heating | High | 17.3 | m³/min | ||
| Medium | 15.3 | m³/min | |||
| Low | 12.3 | m³/min | |||
| Silent operation | 11.2 | m³/min | |||
| Piping connections | Drain | 16 | |||
| Gas | OD | 15.9 | mm | ||
| Liquid | OD | 6.4 | mm | ||
| Power input | Cooling | Nom. | 0.037 | kW | |
| Heating | Nom. | 0.041 | kW | ||
| Power supply | Frequency | 50 | Hz | ||
| Name | V1 | ||||
| Phase | 1~ | ||||
| 220-240 | V | ||||
| Refrigerant | GWP | 675 | |||
| Sound power level | Cooling | 60 | dBA | ||
| Heating | 61 | dBA | |||
| Sound pressure level | Cooling | High | 47 | dBA | |
| Low | 38 | dBA | |||
| Medium | 43 | dBA | |||
| Silent operation | 32 | dBA | |||
| Heating | High | 46 | dBA | ||
| Low | 37 | dBA | |||
| Medium | 42 | dBA | |||
| Silent operation | 34 | dBA | |||
| Weight | Unit | 14.5 | kg |
| Category | Sub Category | Parameter | Condition | Value | Unit |
|---|---|---|---|---|---|
| Compressor | Type | Hermetically sealed swing compressor | |||
| Dimensions | Unit | Depth | 401 | mm | |
| Height | 734 | mm | |||
| Width | 954 | mm | |||
| Energy Efficiency Range | A+++ ~ D | ||||
| Operation range | Cooling | Ambient | Min. | -10 | °CDB |
| Max. | 46 | °CDB | |||
| Heating | Ambient | Min. | -15 | °CWB | |
| Max. | 18 | °CWB | |||
| Piping connections | Additional refrigerant charge | 0.02 (for piping length exceeding 10m) | kg/m | ||
| Level difference | IU | OU | Max. | 20 | |
| Piping length | OU | IU | Max. | 30 | |
| Power supply | Frequency | 50 | Hz | ||
| Phase | 1~ | ||||
| 220-240 | |||||
| Refrigerant | Charge | 1.15 | kg | ||
| 0.78 | |||||
| GWP | 675 | ||||
| Type | R-32 | ||||
| Sound pressure level | Cooling | Nom. | 47 | dBA | |
| Heating | Nom. | 48 | dBA | ||
| Weight | Unit | 55 | kg |
| Category | Sub Category | Parameter | Condition | Value | Unit |
|---|---|---|---|---|---|
| Cooling capacity | Max. | 8.5 | kW | ||
| Min. | 2.3 | kW | |||
| Nom. | 7.1 | kW | |||
| Heating capacity | Max. | 10.2 | kW | ||
| Min. | 2.3 | kW | |||
| Nom. | 8.2 | kW | |||
| Nominal efficiency | Annual energy consumption | 1172 | kWh | ||
| COP | 3.19 | ||||
| EER | 3.03 | ||||
| Energy labeling Directive | Cooling | B | |||
| Heating | D | ||||
| Space cooling | Annual energy consumption | 401 | kWh/a | ||
| Capacity | Pdesign | 7.1 | kW | ||
| Energy efficiency class | A++ | ||||
| SEER | 6.2 | ||||
| Space heating (Average climate) | Annual energy consumption | 2116 | kWh/a | ||
| Capacity | Pdesign | 6.2 | kW | ||
| Energy efficiency class | A+ | ||||
| Pdh Heating capacity at -10° | 5.01 | kW | |||
| SCOP/A | 4.1 |
Searched Code: RXM71A
Key Features
- Pair application
- Bluevolution range: lower environmental impact
- Outdoor units with swing compressor
Technical Specifications
| Category | Sub Category | Parameter | Condition | Value | Unit |
|---|---|---|---|---|---|
| Compressor | Type | Hermetically sealed swing compressor | |||
| Dimensions | Unit | Depth | 401 | mm | |
| Height | 734 | mm | |||
| Width | 954 | mm | |||
| Energy Efficiency Range | A+++ ~ D | ||||
| Operation range | Cooling | Ambient | Min. | -10 | °CDB |
| Max. | 46 | °CDB | |||
| Heating | Ambient | Min. | -15 | °CWB | |
| Max. | 18 | °CWB | |||
| Piping connections | Additional refrigerant charge | 0.02 (for piping length exceeding 10m) | kg/m | ||
| Level difference | IU | OU | Max. | 20 | |
| Piping length | OU | IU | Max. | 30 | |
| Power supply | Frequency | 50 | Hz | ||
| Phase | 1~ | ||||
| 220-240 | |||||
| Refrigerant | Charge | 1.15 | kg | ||
| 0.78 | |||||
| GWP | 675 | ||||
| Type | R-32 | ||||
| Sound pressure level | Cooling | Nom. | 47 | dBA | |
| Heating | Nom. | 48 | dBA | ||
| Weight | Unit | 55 | kg |
Returns are processed only when the item is returned back to us, no exceptions. If the package is still in transit, we cannot process the return. To be eligible for a return, your item must be unused and in the same condition as it was when you received it, and if the item issue cannot be resolved or fixed.