Product Details
Daikin Altherma low temperature monobloc
Reversible air to water monobloc system, ideal when indoor space is limited
Key Features
- Possible to combine with domestic hot water
- Separate back-up heater kit
- Monobloc all-in-one concept including hydraulic parts
- WLAN cartridge included
- Heating and cooling air to water heat pump
Energy Labels
- Energy Class - Space Heating - Low Temperature
- Energy Label
- Energy Class - Space Heating - Medium Temperature
Technical Specifications
| Category | Sub Category | Parameter | Condition | Value | Unit |
|---|---|---|---|---|---|
| Type | Link | ||||
| Energy Class - Space Heating - Low Temperature | |||||
| Energy Class - Space Heating - Medium Temperature |
| Category | Sub Category | Parameter | Condition | Value | Unit |
|---|---|---|---|---|---|
| COP | 5.10 (1) , 3.65 (2) | ||||
| Compressor component | Main power supply | Phase | 3N~ | ||
| 220 | V | ||||
| Cooling capacity | Nom. | 4.86 (1) , 4.52 (2) | kW | ||
| Dimensions | Unit | Depth | 362 | mm | |
| Height | 770 | mm | |||
| Width | 1250 | mm | |||
| EER @ | 5.91 (1) , 3.32 (2) | ||||
| Heating capacity | Nom. | 4.30 (1) , 4.60 (2) | kW | ||
| Operation range | Cooling | Ambient | Min. | 10 (3) | °CDB |
| Max. | 43 | °CDB | |||
| Water side | Min. | 5 (3) | °C | ||
| Max. | 22 | °C | |||
| Domestic hot water | Ambient | Min. | -27 | °CDB | |
| Max. | 35 | °CDB | |||
| Water side | Min. | 25 | °C | ||
| Max. | 55 (3) | °C | |||
| Heating | Water side | Min. | 9 (3) | °C | |
| Max. | 65 (3) | °C | |||
| Power input | Cooling | Nom. | 0.820 (1) , 1.36 (2) | kW | |
| Heating | Nom. | 0.840 (1) , 1.26 (2) | kW | ||
| Power supply | Frequency | 50 | Hz | ||
| Name | V3 | ||||
| Phase | 1~ | ||||
| 230 +/-10% | V | ||||
| Refrigerant | Charge | 1.35 | kg | ||
| 0.91 | tCO2Eq | ||||
| GWP | 675 | ||||
| Type | R-32 | ||||
| Sound power level | Cooling | Nom. | 61.0 (1) | dBA | |
| Heating | Nom. | 58.0 (1) | dBA | ||
| Sound pressure level | Cooling | Nom. | 48.0 (1) | dBA | |
| Heating | Nom. | 44.0 (1) | dBA | ||
| Space heating | Average climate water outlet 35°C | General | SCOP @ | 4.54 | |
| Seasonal space heating eff. class | A+++ | ||||
| Average climate water outlet 55°C | General | SCOP @ | 3.29 | ||
| Seasonal space heating eff. class | A++ | ||||
| Weight | Unit | 88 | kg |
| Category | Sub Category | Parameter | Condition | Value | Unit |
|---|---|---|---|---|---|
| Type | Link | ||||
| Energy Class - Space Heating - Low Temperature | |||||
| Energy Class - Space Heating - Medium Temperature |
Returns are processed only when the item is returned back to us, no exceptions. If the package is still in transit, we cannot process the return. To be eligible for a return, your item must be unused and in the same condition as it was when you received it, and if the item issue cannot be resolved or fixed.