Product Details
Heat pump convector
The optimised cooling and heating combination of efficiency, comfort and flexibility
Key Features
- Includes remote control
- High heating/cooling capacity
- Wall mounted indoor unit
- Optimized for combination with heat pumps
- Pipe connection on the right hand side
Technical Specifications
| Category | Sub Category | Parameter | Condition | Value | Unit |
|---|---|---|---|---|---|
| Casing | Colour | RAL 9003 | |||
| Material | Sheet metal | ||||
| Control systems | Infrared remote control | For FWXT-ATV3(C)(CL) | |||
| Integrated on indoor unit | Yes | ||||
| Cooling capacity | 7/12°C | Max. | 1.24 | kW | |
| Med. | 0.88 | kW | |||
| Min. | 0.49 | kW | |||
| Current | Maximum running current | Cooling | 0.16 | A | |
| Heating | 0.16 | A | |||
| Dimensions | Packed unit | Depth | 210 | mm | |
| Height | 490 | mm | |||
| Width | 1030 | mm | |||
| Unit | Depth | 128 | mm | ||
| Height | 335 | mm | |||
| Width | 902 | mm | |||
| Electrical power consumption | Max. | 19 | W | ||
| Standby | 3 | W | |||
| Fan speed | Max. | 1500.00 | rpm | ||
| Med. | 1100.00 | rpm | |||
| Min. | 680.00 | rpm | |||
| Heat exchanger | Charging | Operating pressure | 10 | bar | |
| Quantity | 1 | ||||
| 0.5 | |||||
| Heating capacity | 45/40°C | Max. | 1.50 | kW | |
| Med. | 1.00 | kW | |||
| Min. | 0.55 | kW | |||
| Operation range | Cooling | Water side | Min. | 5 | °C |
| Max. | 18 | °C | |||
| Heating | Water side | Min. | 30 | °C | |
| Max. | 85 | °C | |||
| Indoor installation | Ambient | Min. | 0 | °CDB | |
| Max. | 45 | °CDB | |||
| Packing | Material | Carton | |||
| Weight | 1 | kg | |||
| Power input | Max. | 0.02 | kW | ||
| Med. | 0.01 | kW | |||
| Min. | 0.01 | kW | |||
| Power supply | Frequency | 50 | Hz | ||
| Phase | 1~ | ||||
| 230 | |||||
| Sensible cooling capacity | 7/12°C | Max. | 0.98 | kW | |
| Med. | 0.70 | kW | |||
| Min. | 0.37 | kW | |||
| Sound power level | Max. | 53.0 | dBA | ||
| Med. | 46 | dBA | |||
| Min. | 35 | dBA | |||
| Water circuit | Piping material | COPPER | |||
| Pressure | Heating | Max. | 10 | bar | |
| water flow rate | Cooling | 7/12°C | Min. | 80.00 | |
| Med. | 150.00 | ||||
| Max. | 210.00 | ||||
| Heating | 45/40°C | Min. | 100.00 | ||
| Med. | 170.00 | ||||
| Max. | 260.00 | ||||
| water pressure drop | Cooling | 7/12°C | Min. | 4.80 | |
| Med. | 10.50 | ||||
| Max. | 11.70 | ||||
| Heating | 45/40°C | Min. | 5.10 | ||
| Med. | 12.00 | ||||
| Max. | 16.30 | ||||
| 3/4 | |||||
| Weight | Packed unit | 15 | kg | ||
| Unit | 14 | kg |
Returns are processed only when the item is returned back to us, no exceptions. If the package is still in transit, we cannot process the return. To be eligible for a return, your item must be unused and in the same condition as it was when you received it, and if the item issue cannot be resolved or fixed.